The manufacturer of the sliding table saw and the ruler tell you the operation items of the sliding table saw

Before precision sliding table saw operation


  1. It is necessary to ensure the threaded connection between the serrated pad and the nut and each part. If there is looseness, the device must be connected before starting the equipment.


       2. Check whether the serrations of the precision table saw are sharp, the serrations must be flat, the serrations must be sharp, no two teeth can be missing in a row, the length of the crack must not exceed 20 mm, the crack must be stopped at the end of the crack, and the testing machine confirms the table saw Whether it works normally for about 1 minute.


  3. Check the rotation direction of the saw tooth of the precision table saw, and confirm whether the rotation direction of the saw tooth is correct. Sliding table saw


  4. Check whether there are foreign objects such as wrenches, bolts, etc. on the work surface, and confirm that the work surface is clean before proceeding.


   5. Check whether the mountain plate is loose or deformed during positioning, and ensure that the positioning plate has been fixed in place.


   6. After confirming that it is correct, open the vacuum valve and prepare for operation.


   7. Fill in the inspection record of the precision table saw.


   Pushing the table saw at work


   1. After the serrations of the precision table saw reach the rated speed, put the material into operation. It is forbidden to place heavy objects and heavy pressure on the table to prevent the deformation of the table surface from affecting the processing accuracy.


   2. When the machine tool is abnormal, the power supply should be cut off immediately, the work should be stopped, and a special person should be assigned for maintenance and debugging. The machine tool should not work with illness.


  3. The equipment must be operated with the circular saw blade with a protective cover; when putting in the material, please firmly stick to the workbench and the backing plate, and do not put your hands close to the saw teeth, otherwise it will cause dangerous accidents. Sliding table saw


  4. For the materials to be processed, the saw teeth of the wood must be checked for nails, gravel and other foreign objects, so as to prevent foreign objects from flying out or damaging the teeth.


  5. When the saw line is offset, in order not to damage the saw blade, it must be modified slowly without violent prying. 6. The operator shall not stand in the direction of the saw tooth and the centrifugal force of rotation to operate, and the arm shall not go over the saw tooth to work.


  After pushing the table saw to work


   1. Cut off the power, clean the machine, clean the remaining things, and add lubricating oil to each part.


  2. Keep the guide rail (always wipe with a soft cloth with butter) and the drive wheel clean. Sliding table saw


   3. Cut off the power supply after the machine operation is over, and do not leave until the machine is completely stopped.